特点: |
|
◥ 电压输入通过开关切换 |
|
◥ 100%满载老化 |
|
◥ 自然风冷、高可靠 |
|
◥ 成本低 |
|
◥ 体积小 |
|
|
|
|
|
|
|
|
R-120D5+12S "S" 代表有远程开关功能 |
|
|
|
|
|
|
|
|
电气规格 |
|
型号 |
R-120D5+12 |
R-120D24+12R |
|
输出通道 |
HC1 |
HC2 |
HC1 |
HC2 |
|
输出特性 |
输出电压 |
+5V |
+12V |
+24V |
+12V |
|
电压调整范围 |
HC1: 4.4~5.8V |
HC1: 19.7~27.5V |
|
额定电流 |
8A |
6A |
5A |
1A |
|
电流范围 |
0.2~8A |
0.1~6A |
0.1~5A |
0.1~1A |
|
额定功率 |
112W |
132W |
|
纹波与噪声 (最大) |
80mV |
80mV |
80mV |
120mV |
|
输出精度 |
±2% |
±1% |
±1% |
±0.5% |
|
线性调整率 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
负载调整率 |
±2% |
±1% |
±1% |
±0.5% |
|
启动、上升、保持时间 |
500ms,20ms/230VAC;1200ms,30ms/115VAC(满载时) |
|
输入特性 |
输入电压范围 |
176~264VAC/88~132VAC(开关转换),或 200~370VDC |
|
输入电流 |
2A/230V ; 3A/115V |
|
频率范围 |
47~63Hz |
|
效率(Typ) |
>70% |
|
>80% |
>83% |
|
浪涌电流(Typ) |
40A/230V(冷启动) |
|
漏电流 |
<2mA/240VAC |
|
保护 |
过载保护 |
110~150%(保护方式:关闭输出,负载条件去除后自动恢复) |
|
环境参数 |
工作温度、 湿度 |
-25℃~+50℃@100% LOAD,+60℃@60% LOAD;20%-90% RH ,无冷凝 |
|
储藏温度、 湿度 |
-40℃ - +85℃, 10%-95% RH |
|
温度漂移 |
±0.03% /℃(0-50℃) |
|
振动 |
10-500Hz, 2G 10分钟/周期, Y、X 、Z轴各60分钟 |
|
安规和 电磁兼容 |
安全规范 |
MEET GB4943 |
|
耐压 |
I/P-O/P:1.5KVAC ; I/P-FG:1.5KVAC ; O/P-FG:0.5KVAC |
|
绝缘阻抗 |
I/P-O/P:500VDC / 100M Ohms/25℃/70% RH |
|
其它 |
尺寸 |
199*97*38mm(L*W*H) |
|
重量 |
600g |
|
备注 |
1. 所有参数在230VAC输入,额定负载,环温25℃,湿度70%条件下测定; |
|
2. 精度:包括设定误差,线路调整率,负载调整率等; |
|
3. 纹波测试:用30cm长绞线连接电源和负载,负载端并0.1u和47u电容,以20MHz示波器于负载端测得; |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|